Our Film Fills Model (BIO – 12) is engineered specifically for use in the HVAC industry, as well as other sectors where the makeup water quality includes Total Suspended Solids (TSS). This innovative product from BioFlow is designed to meet the rigorous demands of cooling systems that require optimal performance despite challenging water conditions

Film Fills Model (BIO – 12) represents a significant advancement in water treatment technology for the HVAC industry and beyond, offering a robust solution for managing challenging water conditions and enhancing system efficiency. By choosing BioFlow, companies can ensure their cooling systems operate at peak performance, with minimal environmental impact and reduced operational costs.

Enquire Now

Technical Specifications


Characteristics BIO -12
Primary Cooling Towers Application Counterflow
Flute height 12 mm
MOC Rigid PVC (Virgin and reprocessed)
Longitudinal pitch 37.5 mm
UV Stabilization White – Titanium DioxideBlack – Carbon Black
Spiral angle 28°
Std. Sheet sizeL x W 600mm x 300mm
Recommended Max Fill Sheet size L x W 1200 mm x 600 mm
Surface area per unit volume 258 m²/m³
Standard Weight 26.5 Kgs/m3
Maximum continuous Operating temp. 55 °C
Minimum Fill Sheet Finished Thickness 0.175 mm
Standard Followed for Material properties CTI STD-136

Applications


  • Advanced Filtration Capability: The Film Fills Model (BIO - 12) effectively handles high levels of TSS, ensuring that cooling systems operate efficiently without the complications of sediment buildup, which can lead to reduced heat transfer and increased maintenance costs.
  • Durable Construction: Built to withstand continuous use in harsh environments, the Film Fills Model (BIO - 12) is made from materials that resist corrosion and degradation. This durability extends the lifespan of the cooling equipment and reduces the frequency and costs of replacement.
  • Efficient Operation: Designed with efficiency in mind, the Film Fills Model (BIO - 12) enhances the overall performance of cooling systems. By maintaining cleaner water circulation, it allows for better heat exchange and energy efficiency, leading to lower operational costs.

Features & Advantages


  • Enhanced System Reliability: By reducing the impact of TSS on cooling systems, the Film Fills Model (BIO - 12) minimizes the risk of downtime and failures, ensuring consistent operation and reliability.
  • Cost Savings: The reduction in maintenance, energy consumption, and potential system downtime results in significant cost savings over the lifespan of the HVAC system.
  • Improved Water Quality: With the Film Fills Model (BIO - 12), systems experience fewer issues related to poor water quality, such as scaling and fouling, which are common in environments with high TSS.